What Is a Vacuum Decay Leak Test for Flexible Stick Packs?
A vacuum decay leak test is a dry, nondestructive seal integrity testing method standardized under ASTM F2338 that detects hidden leaks in sealed packages by measuring vacuum loss (pressure rise) inside an enclosed evacuated chamber. Because no dyes, tracer gases, or immersion fluids enter the package, passing stick packs remain intact.
Stick packs wrap a single strip of heat-sealable laminate into a narrow tube closed by a longitudinal back seam and top and bottom transverse end seals. Candidate stick pack structures such as PET/PE, PET/AL/PE, and NY/AL/PE are flexible, nonporous packages covered under ASTM F2338 Section 1.1.4.
Under ASTM F2338 Section 5.1, leaks in food, pharmaceutical, and medical packages can admit unwanted gases (most commonly oxygen), harmful microbiological contaminants, or particulates through substrate imperfections or at the seal juncture between mated layers. Detecting those defects before distribution protects product stability and verifies that forming and sealing settings hold across production runs.
Unlike visual inspection or water-bath checks, vacuum decay identifies leaks that are not visibly detectable and works across manual, semi-automatic, and automatic setups. Packaging teams use it both as a development tool for optimizing sealing parameters and as a production quality check for statistical sampling or 100% on-line testing.
Related reading: Stick Pack Film & Machine Compatibility; Fin Seal vs Lap Seal on Stick Packs: Film Width, Seal Layers & Dust Tolerance
What Is the Vacuum Decay Leak Testing Principle and Test Procedure?
The vacuum decay leak testing principle relies on pressure-differential mass transfer: when an enclosed chamber holding a sealed package is evacuated and isolated from the vacuum source, any leak allows headspace gas or volatilized liquid inside the package to enter the chamber, producing a measurable rise in chamber pressure.
Every ASTM F2338 method requires an enclosed test chamber to contain the package and a leak detection system designed with one or more pressure transducers. After loading the stick pack and closing the chamber, the pump evacuates the cavity to the target vacuum level, the system allows flexible walls and chamber pressure to settle, and the transducer monitors vacuum loss during the isolated measurement window.
Two distinct physical mechanisms drive that pressure rise. In dry powder or granule stick packs with headspace gas, gas flows directly through a pinhole or seal channel into the evacuated cavity. When testing leaks that may be partially or completely plugged with liquid contents, ASTM F2338 requires evacuating the test chamber below the liquid's vaporization pressure so trapped liquid volatilizes and generates a detectable vacuum loss.
Under ASTM F2338 Section 1.3, final test results are reported as a qualitative Accept or Reject decision, but acceptance criteria come from quantitative measurements. Quality teams establish the permissible decay limit by comparing quantitative baseline vacuum decay readings from control, non-leaking packages against measurements from leaking packages and simulated leaks introduced with a calibrated gas flow meter. Whenever measured decay exceeds the permissible limit, the instrument flags a reject through an audible signal, a visual signal, or both.

Scroll horizontally to see all columns. Keyboard: focus the table and use the arrow keys.
| Test Stage | Physical Action in Chamber | Engineering Verification Check |
|---|---|---|
| 1. Setup & Baseline Calibration | Record quantitative vacuum decay on intact non-leaking control packs, known leaking packs, and simulated leaks from a calibrated gas flow meter | Confirm clear separation between non-leaking baseline and simulated leak response before locking Accept/Reject threshold (ASTM F2338 Sec. 1.3) |
| 2. Chamber Loading & Isolation | Place intact stick pack into the enclosed test chamber without introducing dyes, tracer gases, or immersion fluid | Verify chamber gasket closure and confirm any porous barrier surface is physically masked to prevent rapid vacuum loss (ASTM F2338 Sec. 5.2) |
| 3. Chamber Evacuation | Evacuate chamber to the target vacuum level using the vacuum source | Evacuate below the liquid vaporization pressure whenever liquid contents may partially or completely plug a leak (ASTM F2338 Sec. 1.2) |
| 4. Volume Stabilization | Hold briefly after reaching target vacuum so flexible laminate walls stop stretching into a stable volume configuration | Confirm unrestrained pouch expansion is controlled so wall movement does not mimic leak pressure rise |
| 5. Decay Measurement & Decision | Isolate the chamber and monitor pressure rise (vacuum loss) with one or more pressure transducers | Trigger audible or visual reject alarm whenever measured vacuum decay exceeds the permissible limit (ASTM F2338 Sec. 5.4) |
How Does the ASTM F2338 Vacuum Decay Method Work Across Package Types?
ASTM F2338 (Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method) defines four nondestructive test package classes and links each class to verified detection sensitivities established in precision and bias studies. The U.S. FDA recognizes ASTM F2338-09 (Reapproved 2020) as a complete consensus standard alongside supportive ISO 11607-1 and ISO 11607-2 packaging validation publications, while ASTM F2338-24 is the active revision.
The four covered classes are rigid and semi-rigid non-lidded trays (Section 1.1.1), trays or cups sealed with porous barrier lidding material (Section 1.1.2), rigid nonporous packages (Section 1.1.3), and flexible nonporous packages (Section 1.1.4). Barrier foil and multilayer polymer stick packs fall directly into Section 1.1.4, where Section 1.2.5 states that hole defects of at least 5 µm in diameter can be detected for gas leakages.
ASTM F2338 also publishes verified target vacuum references across other package classes that illustrate how sensitivity shifts with material porosity and liquid content. For rigid nonporous packages tested for headspace gas leakage, holes of at least 5 µm were detected in plastic screw-cap bottles at –500 mbar (–5·E4 Pa). For liquid leakage in rigid nonporous packages, water-filled glass syringes verified 5 µm hole detection when evacuated to about +1 mbar absolute.
By contrast, porous lidding changes the detection floor substantially. In trays sealed with porous barrier lidding tested at –400 mbar, ASTM F2338 verified detection down to 100 µm tray wall defects and 125 µm seal channel defects, and Section 5.2 emphasizes physically masking or blocking off any porous barrier surface so gas migration through the porous material does not cause rapid loss of chamber vacuum. For stick pack buyers considering paper/PE or coated porous structures, confirming nonporous barrier behavior before choosing test limits prevents false rejects.
Scroll horizontally to see all columns. Keyboard: focus the table and use the arrow keys.
| ASTM F2338 Package Class | Reference Target Vacuum | Verified Detection Limit | Stick Pack QC Relevance |
|---|---|---|---|
| Flexible, nonporous packages (Sec. 1.1.4 / 1.2.5) | Product- and package-specific calibrated vacuum (below vapor pressure for liquid-plugged leaks) | Hole defects of at least 5 µm diameter for gas leakages | Primary class for PET/PE, PET/AL/PE, and NY/AL/PE barrier stick packs |
| Rigid, nonporous packages — gas leakage (Sec. 1.1.3 / 1.2.3) | –500 mbar (–5·E4 Pa) for plastic screw-cap bottles; +250 mbar or +1 mbar abs for air-filled glass syringes | Hole defects of at least 5 µm diameter | Benchmark illustrating nonporous gas-leak floor when package walls do not flex |
| Rigid, nonporous packages — liquid leakage (Sec. 1.2.4) | About +1 mbar absolute (water-filled glass syringes) | Hole defects of at least 5 µm diameter | Demonstrates deep vacuum requirement below liquid vaporization pressure for aqueous leaks |
| Porous-lidded trays or cups (Sec. 1.1.2 / 1.2.2) | –400 mbar with porous barrier surface physically masked | At least 100 µm wall defects; 125 µm wire seal channel defects | Relevant warning if evaluating porous paper structures that bleed gas without masking |
What Equipment, Chamber Tooling, and Failure Modes Govern Stick Pack Tests?
Reliable vacuum decay leak testing on flexible stick packs depends on pairing a pressure-transducer leak detector with close-fitting chamber tooling tailored to the stick pack's finished geometry, while guarding against two primary failure modes: flexible pouch expansion in an oversized chamber and liquid-plugged channels tested at too shallow a vacuum.
Because stick packs are flexible rather than rigid glass or molded plastic, differential pressure causes unrestrained pouch walls to expand and stretch. As documented in ASTM F2095 Section 5.4 and Section 5.5 for flexible package decay testing, an unrestrained flexible package must stop stretching and reach a stable volume configuration before a valid decay reading can be taken, whereas rigid restraining surfaces against the package walls limit and stabilize package volume. In a vacuum decay chamber with excessive dead space, ongoing pouch ballooning compresses the remaining chamber air and mimics a leak pressure rise, producing false-positive rejects.
The second critical failure mode affects liquid, gel, and syrup stick packs: false-negative passes caused by liquid plugging. Under ASTM F2338 Section 1.2, when product liquid partially or completely plugs a seal channel or pinhole, gas cannot escape at moderate vacuum. Unless the test chamber is evacuated below the liquid's vaporization pressure so the trapped liquid volatilizes into vapor, a leaking liquid stick pack can pass undetected.
In multi-lane stick pack production, chamber testing works best when paired with disciplined lane-separated sampling. Before adjusting machine settings, collect test packs from each active lane and keep them labeled separately by lane, time, and whether the machine was in steady running or had just restarted. When every lane shows vacuum decay rejects from the same moment, inspect shared web inputs such as the film roll, product batch, and common sealing settings; when rejects stay confined to one lane, inspect that lane's forming, dosing, alignment, powder handling, liquid shutoff, wrinkles, or damaged edges.
Related reading: Stick Pack Machine Problems and Solutions: Multi-Lane Troubleshooting, Seal Leaks & Dose Drift; Liquid Stick Packs: Barrier Films, Tear Openings & Seal Integrity

Discuss this configuration
Discuss on WhatsAppHow Does Vacuum Decay Compare to Bubble, Dye Penetration, Pressure Decay, and Seal Strength Tests?
Vacuum decay (ASTM F2338) complements rather than replaces diagnostic localization and mechanical bond tests: it provides nondestructive whole-pack leak screening down to 5 µm gas holes, whereas bubble emission tests target gross leaks, dye penetration destructively locates channel paths, pressure decay punctures the pack, and ASTM F88 measures mechanical peel strength rather than hermeticity.
Water-bath vacuum bubble emission under ASTM D3078 submerges flexible packages containing headspace gas in an immersion fluid inside a transparent vacuum chamber withstanding roughly one atmosphere pressure differential. ASTM D3078 is limited to gross leaks of 1 × 10⁻⁵ atm·cm³/s (1 × 10⁻⁶ Pa·m³/s) or less, and its scope explicitly warns that viscoelastic product behavior, entrapped air, or internal positive pressure forcing product into the opening can plug small leaks. Internal pressurization bubble testing under ASTM F2096 is destructive because it enters the package to supply internal air pressure, and its method sensitivity is limited to gross leaks down to 250 µm (0.010 in.) with 81% probability.
Dye penetration test packaging methods for nonporous flexible barriers follow ASTM F3039-23. Method A detects and locates edge-seal channel leaks of at least 50 µm (0.002 in.), and Method B detects flat-sheet holes of at least 10 µm (0.00039 in.), but ASTM F3039 Sections 4.4 and 4.5 state clearly that the procedures are destructive, qualitative go/no-go checks that cannot quantify leak size and disqualify tested packs from sale. Peer-reviewed pouch integrity research by Moghimi and Park further established a 15 µm critical integrity threshold in flexible barrier pouches, measured visual injection dye detection at only 4% to 30% for 25 µm and 50 µm channels (rising to 64% and 96% under vacuum dye penetration), and showed that trapped airlocks inside micro-channels can block liquid dye ingress while microbial challenge tests remain probabilistic and destructive.
Pressure decay under ASTM F2095 is likewise destructive because it requires leak-tight entry into the pouch to inject pressurized air or nitrogen, and Section 1.1 restricts enclosed-product testing to solid contents whose seals and surfaces do not contact water, oils, or other liquid. Finally, a seal strength test under ASTM F88/F88M-23 measures the tensile force required to separate a cut seal strip and identifies the specimen failure mode; stick pack quality teams must evaluate separation force, failure mode, and whole-pack leakage as distinct observations because a high peel value does not rule out a localized micro-channel leak.
Related reading: Stick Pack Machine FAT Checklist; Stick Pack Machine Sample Testing

Scroll horizontally to see all columns. Keyboard: focus the table and use the arrow keys.
| Test Method & Standard | Sample Impact | Verified Detection Limit / Output | Key Limitation | Best Stick Pack QC Role |
|---|---|---|---|---|
| Vacuum Decay (ASTM F2338-24) | Nondestructive; dry chamber, no dyes or immersion fluid | Accept/Reject from quantitative baseline; gas holes of at least 5 µm in flexible nonporous packs | Requires close-fitting chamber tooling and vacuum below vapor pressure for liquid-plugged leaks | Routine statistical QC sampling, sealing optimization, or 100% on-line screening |
| Vacuum Bubble Emission (ASTM D3078) | Wet immersion in transparent 1 atm vacuum chamber | Gross leaks limited to 1 × 10⁻⁵ atm·cm³/s (1 × 10⁻⁶ Pa·m³/s) or less; visual bubbles | Small leaks missed due to viscoelastic product, entrapped air, or product plugging | Low-cost gross-leak screening on pouches containing headspace gas |
| Internal Pressurization Bubble (ASTM F2096) | Destructive (requires entry into package for internal air) | Gross leaks down to 250 µm (0.010 in.) at 81% probability | Destroys tested pack; misses micro-channels smaller than 250 µm | Laboratory gross-leak verification on oversized or non-standard pouches |
| Nonporous Dye Penetration (ASTM F3039-23) | Destructive; exposed packs cannot be used for final product | Qualitative go/no-go; locates 50 µm (0.002 in.) edge-seal channels (Method A) or 10 µm sheets (Method B) | Non-quantitative; trapped airlocks and low injection detection (4% to 30% at 25–50 µm) limit sensitivity | Root-cause channel localization on stick packs already rejected by vacuum decay |
| Flexible Pressure Decay (ASTM F2095) | Destructive (punctures pouch for internal air/nitrogen entry) | Leaks of 1 × 10⁻⁴ sccs or greater (volume-dependent), with or without restraining plates | Excludes seals or surfaces contacting water, oils, or other liquid; destroys sample | Off-line dry-pouch leak verification using restraining plates |
| Seal Strength Peel Test (ASTM F88/F88M-23) | Destructive (cuts test strip across seal) | Measures force to separate seal strip and identifies specimen failure mode | Does not test whole-pack hermeticity or detect localized micro-channels | Paired mechanical bond check alongside vacuum decay during setup and FAT |
Sources
Regulatory consensus standards, ASTM International test method scopes, and peer-reviewed flexible packaging integrity research cited in this guide:
Further reading: U.S. FDA CDRH Recognized Consensus Standards — ASTM F2338-09 (Reapproved 2020) Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method; ASTM International — ASTM F2338-24 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method; ASTM International — ASTM D3078-02(2021)e1 Standard Test Method for Determination of Leaks in Flexible Packaging by Bubble Emission; ASTM International — ASTM F2096-11(2019) Standard Test Method for Detecting Gross Leaks in Packaging by Internal Pressurization (Bubble Test); ASTM International — ASTM F3039-23 Standard Test Method for Detecting Leaks in Nonporous Packaging or Flexible Barrier Materials by Dye Penetration; ASTM International — ASTM F2095-07(2021) Standard Test Methods for Pressure Decay Leak Test for Flexible Packages With and Without Restraining Plates; U.S. FDA CDRH Recognized Consensus Standards — ASTM F88/F88M-23 Standard Test Method for Seal Strength of Flexible Barrier Materials; NIH PubMed Central — Moghimi & Park (2017), Leakage assessment of flexible pouches using dye penetration test with correlation to modeled bacterial aerosol challenge test
Common Questions
Is a vacuum decay leak test nondestructive for stick packs?
Yes. Under ASTM F2338, vacuum decay tests sealed packages inside an enclosed evacuated chamber without introducing dyes, tracer gases, or immersion fluids, so non-leaking stick packs are not punctured or contaminated during testing.
What leak size can ASTM F2338 detect in flexible nonporous stick packs?
ASTM F2338-24 Section 1.2.5 states that flexible, nonporous packages can be tested by vacuum decay and that hole defects of at least 5 µm in diameter can be detected for gas leakages, with acceptance criteria calibrated against non-leaking control packs, leaking packs, and a calibrated gas flow meter.
Why can a liquid-filled stick pack pass a shallow vacuum decay test even when it leaks?
Liquid product located in or near a seal defect can partially or completely plug the leak path. ASTM F2338 Section 1.2 specifies evacuating the test chamber to a pressure below the liquid's vaporization pressure so trapped liquid volatilizes and produces a measurable vacuum loss.
Why do flexible stick packs need close-fitting chamber tooling for vacuum decay?
Flexible packages expand and stretch under pressure differentials and must reach a stable volume configuration before measurement. Close-fitting contoured chamber cavities or restraining surfaces limit pouch expansion and dead air space so wall creep does not mimic a leak pressure rise.
Can an ASTM F88 seal strength test replace a vacuum decay leak test?
No. ASTM F88/F88M-23 measures the mechanical force needed to separate a cut seal strip and identifies specimen failure mode, whereas vacuum decay screens the whole sealed package for leakage. Separation force, failure mode, and leakage must be evaluated as distinct observations.
When should QC use dye penetration (ASTM F3039) alongside vacuum decay?
Use nondestructive ASTM F2338 vacuum decay to screen routine production samples or run 100% on-line checks, and apply destructive ASTM F3039 dye penetration to rejected packs when engineering needs to pinpoint the exact location of an edge-seal channel of 50 µm or larger.